Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| air_quality_monitor_ii [2020/03/29 13:17] – [Footnotes] tedem | air_quality_monitor_ii [2021/06/11 03:53] (current) – [Overview] werk_ag | ||
|---|---|---|---|
| Line 2: | Line 2: | ||
| ====== Air Quality Monitor II ====== | ====== Air Quality Monitor II ====== | ||
| + | |||
| ===== Overview ===== | ===== Overview ===== | ||
| + | |||
| + | **NOTE: There is a new version of this device, the [[: | ||
| The WeatherDuino Air Quality Monitor II measures PM2.5 and PM10 dust particles which are important indicators of air pollution.\\ | The WeatherDuino Air Quality Monitor II measures PM2.5 and PM10 dust particles which are important indicators of air pollution.\\ | ||
| - | Based on the PM2.5 readings, | + | Based on the PM2.5 and PM10.0 |
| The Air Quality Monitor can also be used to monitor CO< | The Air Quality Monitor can also be used to monitor CO< | ||
| \\ | \\ | ||
| The AQM II was designed to be installed in places with WiFi Coverage. It can also work without a WiFi connection but several functions will be unavailable. | The AQM II was designed to be installed in places with WiFi Coverage. It can also work without a WiFi connection but several functions will be unavailable. | ||
| - | If WiFi isn't available at the location where you intend to install it, you will need to use the previous version of the Air Quality Monitor (available while stocks last). | + | {{https:// |
| - | + | ||
| - | {{https:// | + | |
| Line 31: | Line 32: | ||
| - | ===== What is needed and is not included: | + | ===== What is needed and is not included: ===== |
| - | - Power supply: 5V - 500mA. Average consumption is bellow | + | - Power supply: 5V - 500mA. Average consumption is below 100mA, but when the sensors are being read, power requirement increases.\\ |
| - Temperature / Humidity sensor (HTU21D or SHT31)\\ | - Temperature / Humidity sensor (HTU21D or SHT31)\\ | ||
| - | - [[http:// | + | - [[http:// |
| - | - One dust particle sensor. Currently two models of dust particle sensors are supported:\\ | + | - One dust particle sensor. Currently two models of dust particle sensors are supported: |
| * [[http:// | * [[http:// | ||
| * [[http:// | * [[http:// | ||
| + | |||
| + | Several scientific reports are listed at the bottom of this web page giving more information on these sensors and evaluating their performance. | ||
| Line 61: | Line 65: | ||
| ===== Technical Data ===== | ===== Technical Data ===== | ||
| - | Power Requirements: | + | Power Requirements: |
| - | Microcontroller: | + | Dust Sensor: PMS7003 or Nova SDS011\\ |
| - | Dust Sensor: PMS7003 or Nova SDS011 \\ | + | CO< |
| - | CO2 Sensor: MH-Z19 (optional) \\ | + | RF Frequency: 433Mhz or 315Mhz < |
| - | RF Frequency: 433Mhz or 315Mhz < | + | |
| ===== Custom Box for the WeatherDuino Air Quality Monitor II ===== | ===== Custom Box for the WeatherDuino Air Quality Monitor II ===== | ||
| Line 91: | Line 95: | ||
| Badura, M., Batog, P., Drzeniecka-Osiadacz, | Badura, M., Batog, P., Drzeniecka-Osiadacz, | ||
| - | Johnston, S.J. and nine others (2019) City Scale Particulate Matter Monitoring Using LoRaWAN Based Air Quality IoT Devices. Sensors 2019, 19, 209; doi: | + | Johnston, S.J. and nine others (2019) City Scale Particulate Matter Monitoring Using LoRaWAN Based Air Quality IoT Devices. Sensors 2019, 19, 209; doi: |